Spectra-precision Survey Pro v4.5 Ranger Reference Manual User Manual Page 274

  • Download
  • Add to my manuals
  • Print
  • Page
    / 475
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 273
Survey Pro Reference Manual
R-266
Turn to Benchmark
Leveling Level Turn to Benchmark.
The Turn to Benchmark screen is used to take a shot at a known
benchmark. When shooting a benchmark that will not be used as the
closing benchmark, the procedure is identical to shooting a leveling
side shot with the exception that this benchmark will be the
backsight in the next setup.
BM Point: is the point name for the
benchmark. This will usually be a new point
when it is a non-closing benchmark and will
usually be the same point as the starting
benchmark when it is the closing benchmark.
Desc: is the optional description for the
benchmark. This is not applicable when
shooting the closing benchmark since the
closing benchmark must already exist in the
current job.
Default Location for New Points: is where
you specify the northing and easting to use when shooting a new
point. This is not applicable when shooting the closing benchmark.
Backsight Point: Lists the details for the current backsight. If this is
the first observation from the current set up, most of the details will
be unknown.
Next > : opens the Take Shot screen (Page R-262) where the
required shots are performed. If the shots are taken to an existing
point, such as when shooting the closing benchmark, the Point Exists
screen, described next, will open where the loop can be closed.
Page view 273
1 2 ... 269 270 271 272 273 274 275 276 277 278 279 ... 474 475

Comments to this Manuals

No comments