Spectra-precision Survey Pro v4.5 Ranger Reference Manual User Manual Page 256

  • Download
  • Add to my manuals
  • Print
  • Page
    / 475
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 255
Survey Pro Reference Manual
R-248
Start Survey – More than One
Matching Base Point
This screen will open when the base is set up on a point that
potentially matches more than one point in the job.
Change > : opens the Start Survey – No
Matching Base screen (Page R-248) where the
base point can be redefined before continuing.
Select a Base Point: allows you to choose a
point from the dropdown list, which contains
all the matching points found in the job.
Next > : opens the Set Up Rover screen.
Start Survey – No
Matching Base Point
This screen will open when the base is set up
on a point that does not match any point in the
job.
Base is set on a new job point: Select this if
the base is set up on a point that is not already
stored in the job. The next screen will then
require that you connect to the rover receiver
and occupy control points to perform a
resection for the base position.
Base is set on an existing job point: Select
this when the base is set up on a point stored
in the job.
Base Point: specifies the name of the base point. This is a new point
name when the base is set on a new point or an existing point name
when the base is set on an existing job point.
Page view 255
1 2 ... 251 252 253 254 255 256 257 258 259 260 261 ... 474 475

Comments to this Manuals

No comments