Spectra-precision Survey Pro v4.6 Ranger Reference Manual User Manual Page 465

  • Download
  • Add to my manuals
  • Print
  • Page
    / 480
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 464
Miscellaneous Screens
R-457
Activate : Activates the selected Smart Target. The active smart
target is marked with the symbol.
Note: It is not necessary to access the Manage Smart Targets screen
to activate a different Smart Target. You can quickly activate a
Smart Target by tapping next to any HR field and then tap the
desired Smart Target from the list that appears.
Edit Smart Target
, Manage Smart Targets, Add or Edit.
The Edit Smart Target screen is used to edit an existing Smart
Target or create a new one.
Name: is the desired name for the Smart
Target.
Target Type: defines the type of target as
being a Prism, Reflectorless, Long Range, which
increases the EDM power, or On Gun, which
uses whichever EDM settings are configured on
the total station (for Leica total stations only).
HR: is the default HR for the Smart Target.
Add Offset to HR: when checked, the offset
entered will always automatically be added to
the HR entered for the Smart Target.
Prism Constant: is the prism constant for the Smart Target.
Note: If a prism constant is entered for a Smart Target while a prism
constant is also set in the total station, the prism constant will be
applied twice, resulting in incorrect distance measurements for every
shot. Be sure the prism constant is set to zero in the total station if
entering a value for a Smart Target, or vice-versa.
Page view 464
1 2 ... 460 461 462 463 464 465 466 467 468 469 470 ... 479 480

Comments to this Manuals

No comments