Survey Menu – GPS Module
R-193
opened and logging of raw GPS measurements for post processing
will start. This will be a stop and go data file, and the site ID and
antenna measurement will be recorded in the file with each point
occupation at the rover.
The rover receiver will monitor the data link until the base reference
position arrives, then Survey Pro will check the point database for a
matching point. If you are using a remote base, Survey Pro will find a
matching point or prompt you to store a new point. If you are using
the base station you have already set with this data collector, then
this check serves as error detection.
Solve Localization
The Solve Localization screen is used to indicate when a horizontal
and vertical localization adjustment is required, and to guide you
through the steps to collect control points and solve the adjustment.
Collect Control>: opens the Control Points
screen, where you can choose local points to use
as GPS control points and occupy them with
the GPS rover.
Solve Localization: displays information about
the current number of GPS control points, and
how many more are needed to have the
minimum number required to solve the
localization.
Solve Localization…: opens the Solve
Localization wizard (Page R-214).
Start Now >: allows you to start surveying now without localizing.
Localization can be performed later, at which time all data collection
points will be updated to the proper local coordinates.